Login | Register
产品中心
Home > Products > Basic chemical raw material series > Nickel fluoride

Nickel fluoride

Molecular formula: NiF2·4H2O

Molecular weight:168.75

Appearance: Green crystal

Purpose: It is used to make printing ink, fluorescent lamp, organic synthetic fluridizer and catalyzer.

Packing: 25kg/ carton

 

Main technical indexes                 

 

Content (based on nickel)              34.0%
Chloride                            ≤0.05%

Sulfate                             ≤0.10%
Copper                             ≤0.01%
Iron                                ≤0.02%
Zinc                                ≤0.08%


<span style="font-size: 16px;"><a href='https://www.huaaochemtech.com/tag/nickel-fluoride' target='_blank' class='key-tag'><font><strong>Nickel Fluoride</strong></font></a> Supplier for Anodizing Chemicals | Huaao</span>

We work with industrial buyers who need a defined nickel fluoride raw material for an established process. For aluminum anodizing and cold sealing, the useful questions begin with chemical form, nickel content, fluoride requirements, and the quality of the finished surface. At Jianli Huaao Technology Co., Ltd., we bring those questions into the supply discussion before an order is agreed.

Our business combines the development and manufacture of aluminum profile surface treatment additives with the trading of electroplating and magnetic raw materials. We review nickel fluoride enquiries through that raw material supply business. Your application and acceptance specification guide the proposed grade, documentation, package, and delivery arrangement.

Nickel fluoride generally means nickel(II) fluoride, with nickel in the +2 oxidation state. Two forms relevant to purchasing are Anhydrous Nickel Fluoride, NiF2, and Nickel Fluoride Tetrahydrate, NiF2·4H2O. The tetrahydrate includes four water molecules in its formula. That difference changes the mass of material associated with a given amount of nickel.

We make the requested form clear in the enquiry, quotation, and supporting documents. If your existing process specifies the tetrahydrate, include that full name and its identity information. If you need the anhydrous material, state it explicitly. Your approved specification gives us a better starting point than a general request for nickel fluoride powder.

Nickel fluoride forms: chemical identity comparison
Reference itemAnhydrous nickel(II) fluorideNickel(II) fluoride tetrahydrate
FormulaNiF2NiF2·4H2O
CAS number10028-18-913940-83-5
Approximate formula mass96.69 g/mol168.75 g/mol
Water molecules in the ideal formula04
Nickel-to-fluorine atom ratio1:21:2

Sources: U.S. Environmental Protection Agency, Substance Registry Services, Nickel fluoride (NiF2), substance record 166694, for the anhydrous identity and formula mass; PubChem, Nickel fluoride (NiF2), tetrahydrate, CID 25021989, for the tetrahydrate identity and formula mass. Water counts and atom ratios follow the displayed formulas. These reference data do not establish Huaao stock availability or a commercial lot specification.

Once identity is confirmed, we look at the characteristics your process actually controls. A successful purchase needs the right chemical form and an agreed acceptance plan, supported by documents that describe the proposed material clearly.

Why Nickel Fluoride Is Used in anodizing processes

We discuss nickel fluoride for anodizing mainly in connection with sealing chemistry. An anodized aluminum surface has a porous oxide layer. Depending on the intended finish, sealing reduces the accessibility of those pores and helps the coating meet its service requirements. The sealing result depends on the oxide produced earlier and the conditions used throughout the finishing line.

Its role in a cold sealing system

Nickel fluoride is associated with established cold sealing systems for anodized aluminum. In these systems, chemical reactions in and around the pores contribute to sealing. Nickel-containing deposits and changes to the oxide are part of the technical explanation. We evaluate the raw material within the complete formulation and process used by your plant.

The commercial sealing product may contain several ingredients. A nickel fluoride raw material and a formulated sealing agent therefore answer different purchasing needs. Tell us whether your team prepares a controlled formulation from individual ingredients or uses an approved finished product. We can then discuss the appropriate product enquiry within our chemical business.

Some established cold sealing systems include a subsequent hydration or treatment stage. We ask you to identify the approved sequence, including rinsing and any later processing. The relevant instructions for the complete system determine how that sequence is operated. A raw material description alone cannot define the finished process.

Applications across aluminum profile finishing

For architectural profiles, decorative parts, and other anodized components, buyers often care about surface appearance and resistance to the expected environment. We connect the raw material specification to the tests used for those parts. The required finish, alloy, anodic coating, and coloring process help determine what your team needs to evaluate.

On a colored anodizing line, we also discuss how your team checks shade, visible deposits, and consistency across a batch. Those observations should be assessed with the sealing-quality results. We want a trial to reflect the actual part and finish rather than a material comparison that overlooks production conditions.

Specialist surface activation work

Published research has examined nickel fluoride tetrahydrate as a surface activator and sealant before electroless nickel-phosphorus coating on anodized AA1050 aluminum. That is a specific research application. If you are evaluating similar work, send us the raw material specification and the characteristics your method requires so we can review the enquiry on that basis.

Technical references: Aluminum Anodizers Council, anodized aluminum sealing guidance; Qualanod Specifications, edition 27 January 2025, discussion of nickel fluoride cold sealing systems; Kocabaş and coauthors, “Nickel fluoride as a surface activation agent for electroless nickel coating of anodized AA1050 aluminum alloy,” Surface and Coatings Technology, 2019. The dated specification is background information; applicable process and acceptance requirements must be confirmed for the customer's work.

What the Composition Figures Mean for Your Purchase

We compare the chemical form before comparing a percentage. Salt assay, elemental nickel content, total fluorine, and water-related results describe different things. A purchasing team can receive two technically correct figures that look inconsistent because the reporting bases differ. We check what each result measures and how it was calculated.

The tetrahydrate includes water of crystallization. That water is part of its ideal formula, so the nickel fraction is lower than in the ideal anhydrous compound. This is a formula difference, not proof that one offered product has more unwanted impurities. We review actual purity and impurity limits separately.

Calculated composition of ideal pure nickel fluoride forms
Comparison basisPure anhydrous NiF2Pure NiF2·4H2O
Theoretical nickel content60.70% by mass34.78% by mass
Theoretical total fluorine content39.30% by mass22.52% by mass
Theoretical crystal-water fraction0.00%42.70% by mass
Nickel in 100 kg of pure compoundApproximately 60.70 kgApproximately 34.78 kg
Pure compound containing 1 kg of nickelApproximately 1.647 kgApproximately 2.875 kg

Calculation sources: EPA Substance Registry Services and PubChem CID 25021989 provide formula masses of 96.69 and 168.75 g/mol. CIAAW gives atomic weights of 58.6934 for nickel and 18.998403162 for fluorine. Element percentages equal the relevant elemental mass in the formula divided by formula mass, multiplied by 100. Crystal-water percentage uses the difference between the displayed formula masses. Results are rounded calculations for ideal compounds, not supply guarantees, measured lot results, or operating instructions.

For a commercial comparison, we return to the agreed specification and relevant lot information. Ask whether a result applies to the material as received or to a defined dry basis. We also clarify whether the reported percentage is an assay expressed as a chemical compound or a direct elemental measurement.

Total fluorine and free fluoride are different measurements

The fluorine percentage calculated from a raw material formula does not describe the measured free fluoride in a working sealing bath. Bath chemistry changes how fluoride is present and measured. We ask your team to use its approved analytical procedure for process control. A bag's calculated composition is useful for material review, while the bath needs its own measurements.

We compare commercial value using the full delivered requirement. Nickel content may help explain differences in price per kilogram, but package suitability, impurities, evaluation costs, freight, and process compatibility also matter. Any change between hydrate forms should pass your technical review before a revised material is introduced.

How We Define the Grade and Supporting Documents

We start with a specification your receiving team can use. It should identify the required nickel fluoride form, acceptance limits, reporting units, and important test methods. Tell us which items are essential to production approval and which are requested for information. We can then review the proposed supply against a clear set of conditions.

Chemical limits that match the application

Depending on the process, your specification may control nickel, fluorine, insoluble matter, or particular impurities. If your formulation limits iron, copper, chloride, sulfate, or another constituent, include the actual value and unit. We review the available evidence for the proposed grade rather than assuming that a general product name covers every limit.

We also clarify how water-related requirements are expressed. A tetrahydrate has defined crystal water in its ideal formula, while other water measurements depend on the method and reporting basis. Terms such as moisture, loss on drying, and water content should be accompanied by the intended test conditions when they form part of acceptance.

Physical condition and solution preparation

Tell us whether your handling system requires information about powder condition, particle size, caking, or package opening. Appearance can help identify an obvious discrepancy, but it cannot establish chemical purity. We agree on any physical requirements that matter and confirm the information available for the offered material.

For solution preparation, define the medium and the approved evaluation method. The chemical form, concentration, mixing conditions, and other ingredients can affect preparation behavior. If your plant controls residue or preparation time, provide those acceptance conditions. A measurable test gives both teams a clearer basis for comparison than a broad description such as easy dissolving.

What we need from a COA and SDS

A certificate of analysis provides relevant lot information, while a safety data sheet describes hazards and handling. The agreed specification defines the purchase requirements. We review these documents together and establish what is needed for supplier approval, shipment, and receiving inspection. Your organization may also require origin information or other supporting records.

If additional analysis is requested, we confirm feasibility, method, timing, and cost before accepting it as an order condition. We also distinguish a sample report used to explain the format from the documents agreed for the actual delivery. Lot references and document revisions should be clear enough for your receiving team to connect them to the material.

For repeat orders, we ask you to identify the current specification revision. A change in the final product or process can alter the required limits even when the raw material name stays the same. We use the current requirement to review the next enquiry and the proposed supply arrangement.

How We Connect a Material Trial to Sealing Quality

We start a trial by asking what the finished aluminum must pass. That may include an agreed sealing test, an appearance check, or a customer-specific performance requirement. Define those outcomes before evaluating a new raw material. The trial can then answer the production question behind the purchase.

Keep the comparison conditions clear

For nickel fluoride cold sealing evaluations, record the approved bath conditions, coating details, treatment sequence, and test timing. Nickel concentration, free fluoride, pH, temperature, and treatment time are relevant process variables. We ask your team to work within its established procedure and document the conditions used to compare the candidate material with an accepted reference.

We also review the context of a reported defect. Alloy, pretreatment, anodizing, coloring, rinsing, and carryover can influence the final surface. If a trial shows haze, deposits, uneven appearance, or an unexpected test result, share the production record alongside the raw material information. That gives the investigation a defined starting point.

Choose tests that fit the coating

Several recognized methods assess aspects of sealing quality. These include dye absorption, electrical admittance, and mass loss after specified acid exposure. We ask which method and acceptance criteria apply to your coating. Each method has its own scope and limitations, and results from different sealing systems may need careful interpretation.

For example, a dye-spot test estimates the coating's absorptive behavior after a defined pretreatment. An admittance test uses an electrical measurement to assess the sealed coating. A mass-loss method examines loss under specified test conditions. We discuss these as evaluation options; your applicable standard or customer agreement determines which method is appropriate.

We keep trial records connected to the material identity and sample reference. Include the specification revision, preparation method, relevant bath measurements, and the time between processing and testing. If your approved sequence includes subsequent hydration or a defined conditioning period, follow that sequence before interpreting the result.

When samples are requested, we confirm availability and terms during the enquiry. We also clarify how the sample relates to the proposed commercial grade. A useful qualification record should tell your team what was evaluated and which supply specification was accepted, so later orders can be reviewed against the same basis.

Evaluation references: “Optimization of the nickel fluoride cold sealing process,” Transactions of the IMF, 1992; ISO 2143:2017, dye-spot testing; ISO 2931:2017, admittance measurement; ISO 3210:2025, mass-loss assessment. Consult the applicable complete method for scope, limitations, test conditions, and interpretation. These references do not establish product approval or a universal pass limit.

The Surface Treatment Experience We Bring

We have focused on aluminum profile surface treatment for more than two decades. Our company is based in the Huazhong Ecological Aluminum Demonstration Industrial Park in Jianli, Hubei. We combine research, technical consulting, production, and sales in our additive business, with raw material trading alongside it.

Our product development covers dozens of pretreatment and finishing series. These include chemical sandblasting agents, polishing products, long-life alkaline etching agents, neutralization brightening agents, electrolytic coloring stabilizers, degreasing and dewaxing agents, chromium-free passivation agents, and sealing agents for different operating temperature ranges.

That range gives us a practical reason to consider the entire finishing sequence. A sealing enquiry may relate to an upstream rinse, a colored finish, or the test used for release. We use our background to make the discussion specific and to identify what information the proposed raw material supply needs to address.

We have production facilities, precision testing instruments, and a quality assurance system for our established chemical business. We also serve as a standing council member of the China Non-Ferrous Metals Processing Industry Association. For a nickel fluoride order, we connect that company background with evidence about the actual offered grade and its available quality documents.

Clear information about the supply arrangement

Our own manufacturing work centers on surface treatment additives. We confirm the proposed nickel fluoride material, available origin information, and supporting records through the raw material supply proposal. If your supplier approval procedure needs producer details or additional analytical information, identify those requirements early so we can review what is available.

We aim to make the technical and commercial descriptions agree. Your laboratory needs a defined material and acceptance method; purchasing needs a quantity, package, price basis, and schedule. We bring those requirements together in the order discussion so both teams can assess the same proposed supply.

Packaging, Handling, Delivery, and Payment

We confirm packing against the product form, net quantity, handling needs, destination, and transport requirements. For solid nickel fluoride, the proposal may involve suitable sealed inner packaging and an appropriate bag or drum arrangement. Available formats and package weights are established for the actual order.

Tell us how your site receives and charges the material. Manual lifting limits, batch size, package-opening arrangements, and the way part-used packages are managed can affect the most practical choice. We discuss net weight, package count, labeling, and pallet details before the shipment is prepared.

Review the SDS before handling

Nickel fluoride requires serious attention to worker exposure and environmental control. Published safety information identifies sensitization, cancer, reproductive, and repeated-exposure hazards, as well as aquatic toxicity. We ask buyers to review the current SDS for the offered material and establish appropriate controls through their workplace assessment.

That review should cover dust containment, protective equipment, storage compatibility, spills, and waste. The site's approved procedures and applicable requirements govern those arrangements. We also ask you to identify any special labeling or document needs during the enquiry so they can be considered before an order is accepted.

Confirm preparation time and transport separately

Lead time depends on chemical form, grade, availability, order quantity, testing, packing, and documentation. We confirm the proposed schedule after reviewing those details. Please state whether your target date means dispatch, arrival, or release for use after receiving inspection. Those dates serve different planning purposes.

We review sea, road, or air transport where permitted and accepted by an appropriate carrier. The current shipment classification, package, quantity, and destination determine the available options. We confirm the relevant transport documents and shipping responsibilities for the specific supply. Transit time is considered separately from material preparation.

Agree on the payment and acceptance terms

We can discuss T/T or a letter of credit, with the final conditions set out in the contract. Currency, payment timing, banking requirements, shipping responsibilities, and document conditions should be settled together. If your bank requires particular wording, raise it early enough for review.

Delivery acceptance should cover the agreed quality indicators, quantity, package identity, and supporting documents. We ask customers to define any receiving tests and inspection period before dispatch. On arrival, compare the material and paperwork with the accepted order and report discrepancies through the agreed procedure.

Safety background: published nickel fluoride tetrahydrate safety data and PubChem CID 25021989 hazard information. The current SDS for the offered form, applicable workplace rules, and the actual shipment documentation govern the specific order.

Questions We Resolve Before a Nickel Fluoride Order

Which form should we include in our enquiry?

We ask you to identify anhydrous nickel fluoride or nickel fluoride tetrahydrate explicitly. Include the CAS number, current specification, and intended use. Your established process requirement determines the form to evaluate. We review the available proposal against those details before confirming supply conditions.

What is the difference between CAS 10028-18-9 and 13940-83-5?

CAS 10028-18-9 identifies anhydrous nickel(II) fluoride, NiF2. CAS 13940-83-5 identifies nickel(II) fluoride tetrahydrate, NiF2·4H2O. We check the name, formula, and identifier together so the quotation, label, and supporting documents describe the same intended material.

Does about 34.78% nickel indicate low purity?

We distinguish nickel content from compound purity. The ideal tetrahydrate contains approximately 34.78% nickel by mass because fluorine and crystal water also contribute to its formula mass. Commercial acceptance depends on the agreed assay, reporting basis, and impurity limits for the proposed product.

Can we replace tetrahydrate with anhydrous nickel fluoride?

We recommend reviewing that as a material change. The forms have different mass contributions and may behave differently during preparation. A calculation of equivalent nickel is one input to the review. Your team should validate the proposed form against the complete formulation and process before introducing it.

Is nickel fluoride a complete cold sealing agent?

We distinguish a raw material enquiry from a formulated product enquiry. A finished cold sealing system may contain several ingredients and have its own operating instructions. Tell us which product type you need so we can discuss the relevant raw material or sealing-agent requirement.

Can total fluorine predict the bath's free fluoride result?

We use formula calculations for material composition, while a working bath requires its approved analytical method. Free fluoride depends on the solution chemistry and measurement procedure. Tell us the control method your process uses so the raw material discussion remains consistent with the plant's actual requirements.

Can you guarantee a sealing-quality result from the raw material?

We agree on the supplied material's specification and supporting documents. Finished sealing quality also depends on the anodic coating, bath condition, processing sequence, and test method. We discuss relevant trial information so your team can evaluate the candidate grade under its approved production conditions.

What determines order quantity, packaging, and delivery time?

We confirm these after reviewing the form, grade, available supply, testing, package requirements, and destination. Send your target use date and receiving restrictions. We can then review a concrete proposal with the relevant preparation and shipment conditions stated for your assessment.

How do we request a nickel fluoride quotation?

Send the required form, specification, application, quantity, destination, and target date. Add your preferred packaging, COA and SDS requirements, and any sample or additional testing needs. We will review the enquiry and confirm the proposed material and commercial terms before order acceptance.

Discuss your nickel fluoride requirement with Huaao. Share the specification your team uses or the questions you need to resolve. We will review the chemical form, quality requirements, documents, packaging, payment, and delivery conditions for the proposed supply.

ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

No search results found!
chat

Online Customer Service

×

This website uses cookies to ensure you get the best experience on our website.

Accept Reject